Devices change. Recalibration keeps the readings stable.
Software updates, noise cancellation and new phones shift speech measures in clinical trials that record on phones. Cephalgo’s speech biomarker readings stay stable across them, recalibrated from the audio alone.
Without recalibration, a phone change reads as disease change
The speaker stays the same. Only the processing on the phone changes, and standard speech measures move with it.
Most measures move
Most standard speech measures shifted when the same recordings were run through three noise-cancellation methods.
No single offset
The measures move in both directions, so one offset for all measures does not work; each measure gets its own shift.
False trends
In simulated year-long studies where no one’s speech changed, phone updates alone produced a trend a standard analysis reports as real. Recalibration reduces that false trend.
Where the processing changes
Before a recording reaches analysis, the device can process it: gain control, compression, noise suppression, codecs. Over a long study that processing can change, and a speech measure can move with it.
Operating system and firmware updates
Processing can change mid-study with an operating system or firmware update.
Browser updates and app releases
A browser update or a new release of the recording app can change it too.
A replaced device
A replacement phone can process speech differently from the one it replaces.
Codec updates
Compressed audio can also change with a Google Play codec update.
Recalibrated from the recordings themselves
Recalibration runs from the audio alone, on any recording device and capture app: your eCOA or app vendor’s recordings, participants’ own phones, study-provided devices or recorders a study already uses.
Find the processing periods
A recording fingerprint assigns each recording to the period in which one processing setting was in force.
Anchor and re-estimate
The components of the multi-stream reading that are most stable across processing states anchor the estimate of each measure’s shift between periods.
Your analysis, unchanged
Measure definitions stay fixed, including your own models’ measures. Only each measure’s shift per processing period is re-estimated, delivered as recalibrated values or a covariate.
Recordings untouched, blind to arm
Recalibration is applied to the measures and runs blind to treatment arm; the audio files are never altered.
The same recordings, processed three ways
Recordings from held-out participants with Parkinson’s and controls were run through three noise-cancellation methods that stand in for phone updates.
Held-out participants
None of these participants’ recordings were used to build the reading; only the noise-cancellation method changes.
Four baselines side by side
Cephalgo multi-stream against Whisper, standard acoustic features, HuBERT and Wav2Vec2, each a single stream, on the same audio.
State of the art for stability
Across the three methods, the multi-stream reading was the most reproducible of the five approaches compared.
Why it moves least
Acoustic-linguistic features, cognitive-linguistic features and deep-learning embeddings respond differently to the recording chain, so when one moves, the others steady the multi-stream reading.
What phone firmware does to speech
We read the capture configuration and calibration files in the stock firmware, recording mode by recording mode.
Dynamic range compression is common
Many Android phones compress the voice-recognition path, and every iPhone model we read compresses its default mode. This changes loudness variability and, with an expander, pauses.
Same series, different chip
The Snapdragon Galaxy S24 Ultra runs a compressor on its voice-recognition path; the Exynos Galaxy S24 does not.
Updates change the chain
Between firmware builds, several Android models changed their capture configuration. On the two iPhone models we compared, minor iOS updates changed the tuning of the measurement recording mode.
Findings shape the setup
These firmware findings decide what we check at enrollment and log with every file; recalibration itself needs only the audio.
What to check in each setup
Each setup meets processing change in different places. Ask these questions of any speech vendor; we answer each one for your protocol.
Fixed device
- Updates
- Device management can delay updates, and some phones can be held at a set build; none holds back every update.
- AskIs the firmware build pinned, and recorded with each file?
- Google Play system updates
- They install at the next reboot and can change software codecs.
- AskIs the audio stored uncompressed?
- A replacement phone
- The same model can arrive with a newer build or a different chip variant.
- AskHow is a replacement phone treated in the analysis?
- App releases
- The recording app decides the audio source, format and in-app processing.
- AskIs the app version logged with every file?
- End of support
- Many Android models have a published security-support window, counted from launch.
- AskDoes support run past the last planned visit?
- Microphone and case
- Dust and case membranes can change what the microphone picks up.
- AskIs the case fixed, and is a per‑participant baseline kept?
BYOD
- Updates
- Operating system and app updates arrive on the participant’s schedule.
- AskAre operating system and app versions logged with every recording?
- Many phone models
- Each phone model brings its own capture chain.
- AskHow are model differences handled?
- Recording route
- Phones offer several recording modes, and none is guaranteed unprocessed.
- AskWhich recording mode is checked at enrollment, and logged?
- Participant settings
- On iPhone the participant can choose a microphone mode in apps that support it, and any phone can take a headset.
- AskAre the microphone mode and input route logged?
- A new phone
- A participant can move to a new phone between sessions.
- AskHow is a step change found and recalibrated?
Every update on record
When a device, operating system, app or analysis version changes, the record shows when, ready for the before-and-after comparison the FDA guidance describes.
Processing periods
Each recording carries its processing period, next to the original and recalibrated readings.
Uncompressed audio
Compressed audio can shift with a codec update; Cephalgo’s capture keeps files uncompressed.
Versions per file
The analysis version is logged with every reading. Cephalgo’s capture app also logs device model, operating system build and app version; browser recordings log what the browser reports.
Noise checked
Every recording, from any app, carries noise, clipping and speech-duration flags read from the audio; with Cephalgo’s capture, a failed check asks for a retake.
“Sponsors should keep a record of the timing and nature of any updates for each DHT.” And if the measurement has changed after an update, “sponsors should compare data from DHTs before and after the update” and “specify how these differences will be addressed in the analysis of the trial prior to unblinding.”
Phone changes and speech biomarkers
Do phone and software changes affect speech measures in clinical trials?
Yes. Operating system updates, app releases, codec updates and replacement phones change audio processing, and most standard speech measures move with it, even when the speaker’s speech has not changed.
How does Cephalgo keep speech biomarker readings stable when phones change?
Cephalgo assigns each recording to a processing period from its audio, then re-estimates each measure’s shift between periods, anchored on the most stable parts of its multi-stream reading.
Does Cephalgo recalibration work with any phone or capture app?
Yes. Cephalgo recalibrates from the audio alone, on any recording device and capture app: eCOA or app vendor recordings, participants’ own phones, study-provided devices or recorders a study already uses.
Is Cephalgo recalibration blind to treatment arm?
Yes. Cephalgo applies recalibration to the speech measures blind to treatment arm, keeps measure definitions fixed, and delivers recalibrated values or a covariate; the audio files are never altered.